Starting up the cleaning device
Prerequisites for
start-up
The following requirements must be met before the cleaning device is started up:
- If present, the cleaning device installation stand is screwed to the underlying surface
- The cleaning device is screwed to the underlying surface
- The gas nozzle clamping device has been adjusted - not on the Robacta Reamer V
Easy Han6P J and if a gas nozzle with an outer diameter of 25 mm ( 0,98 inch) is
used. For more information, see "Adjusting the gas nozzle clamping device"
- The cleaning cutter is fitted
- The lifting device has been adjusted
- If present, the wire cutter has been installed
- If present, the parting agent nebuliser is started up
- If present, the fill-level control sensor is started up
- The compressed air supply has been established
- The functions have been checked manually
- The cleaning device is connected to the robot control
- All coverings are fitted and all safety devices are intact and in their proper place
Start-up The cleaning device starts up when there is an active signal from the robot control.