Weld Process
Gas Flow
The flow rate of the shielding gas is a critical aspect of
the welding process. Too high OR too low will have a
serious impact on weld results.
Rule of thumb for the flow rate: 10 – 12 times the
diameter in l/min of flow
- 1.2mm x 10 = 12 l/min
- 1 l/min = 2.1 CFH
- 12 l/min x 2.1 = 25 CFH
Helium and Hydrogen require about 50% more flow
than other gases due to their lighter weights.
Correct flow rate
Excessive flow rate
Gas Pressure Sensor (4,100,343)
Manually set gas valve that reports a gas error to the weld
system when flow is too low. Only errors out for low flow
and doesn’t report specific flow information.
Digital Gas Sensor (4,100,374)
The specific gas flow is set, regulated, and monitored
using this device. Not only is a low or high flow rate
detected, but the system also reports back specific gas
flow data.
-
--
- 31
31 31
31 -
--
-
Fronius Options
Typically, the weld system opens and closes the gas
valve. If flow monitoring is desired within the system, the
following options are available.