EasyManua.ls Logo

Fronius TPS 3200 MV - Interface and Connectivity

Fronius TPS 3200 MV
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13 SEP 12
/ Battery Charging Systems / Welding Technology / Solar Electronics
Interface
Ethernet (Ethernet IP, WeldCOm)
Each interface signal is converted to a TCP/IP protocol and digitally transferred between the
weldign power supply and the automation controller.
A single bit is used for on/off based interface signals
Multiple bits are put together for form a binary value for variable signals.
The bit-map can be changed (though time-consuming and expensive⁄
Offers the most versatile and capable of all interfaces.
Models
Discrete I/O (Rob 3000, 4000, 5000, 5000 OC)
Each interface signal is indivually wired into the robot/automation controller
Source/sync signal for on/off based interface signals
0-10 VDC analog signal for variable signals
No modification or changes are possible with the signal set.
-
--
- 76
76 76
76 -
--
-
Fieldbus (DeviceNet, Profibus, CANbus)
Each interface signal is converted to a fieldbus protocol and digitally transferred
between the welding power supply and the robot/automation controller
A single bit is used for on/off based interface signals
Multiple bits are put together to form a binary value for variable signals.
No modification or changes are possible with the signal set.

Table of Contents