EasyManua.ls Logo

Fronius TPS 3200 MV - Motor Draw Test; Output Voltage Test

Fronius TPS 3200 MV
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13 SEP 12
/ Battery Charging Systems / Welding Technology / Solar Electronics
Processes
Functional Tests
Step 1:
Step 1:Step 1:
Step 1: Press the Parameter Selection button (A⁄ until the
main motor indicator (B⁄ is lit.
Step 2:
Step 2:Step 2:
Step 2: First test the motor without load by opening up the
drive rolls on the wire feeder
Step 3:
Step 3:Step 3:
Step 3: Press the Wire Feed button (C⁄ and check the left
most display (D⁄. It should be ~.7 amps (+/- 1
amp⁄.
Step 4:
Step 4:Step 4:
Step 4: Check the motor under load by closing the drive
rolls on the wire feeder
Step 5:
Step 5:Step 5:
Step 5: Press the Wire Feed button (C⁄ and check the left
most display (D⁄. It should be ~1.0 amps. (+/-
20%⁄
A
AA
A
B
BB
B
C
CC
C
D
DD
D
Step 1:
Step 1:Step 1:
Step 1: Press the Parameter Selection button (A⁄ until the
voltage indicator (B⁄ is lit.
Step 2:
Step 2:Step 2:
Step 2: Disconnect the ground connection from the front of
the power supply.
Step 3:
Step 3:Step 3:
Step 3: Press the process select button (C⁄ until the Stick
indicator (D⁄ lights up.
Step 4:
Step 4:Step 4:
Step 4: The right most display (E⁄ should indicate 40V
within one minute.
Step 5:
Step 5:Step 5:
Step 5: Press the process select button (C⁄ until the
process changes to something other than TIG or
Stick.
A
AA
A
B
BB
B
C
CC
C
E
EE
E
Motor Draw Test
Motor Draw TestMotor Draw Test
Motor Draw Test
Output
Output Output
Output Voltage
VoltageVoltage
Voltage Test
TestTest
Test
D
DD
D
-
--
- 54
54 54
54 -
--
-

Table of Contents