Welder Error Codes
DSP xxx
Error with the Digital Signal Processor – Reload firmware/database or replace UST
EFD xxx
Error with the wire feed system, refer to wire feeder error codes for more details
Err 049, 051, and 052
Error detected in mains power input (phase missing or voltage too low/high). Check mains and then replace NT 24
Err 050
Intermediate circuit imbalance. Further troubleshooting needed
Err IP
Primary transformer over-current detected. Check the secondary power module and the BPS board.
Err PE
Voltage detected on earth ground. Check for isolation between welding ground points and earth ground points.
No H2O
Error with the coolant system, check cooler for operation and system for good flow.
No Prg
Synergic line selected doesn’t exist. Verify synergic line settings, reprogram UST, or replace UST.
STOP
Communication or E-Stop condition with robot. Check for Robot Ready and Error Reset signals from robot.
Tsx xxx and Tpx xxx
Internal temperature errors on the secondary or primary side. Check for duty cycle and proper air flow.