6-2 6. KOGANEI
6.1.1 IBFL-TC
Communication Setting
Editor
Communication setting
(Underlined setting: default)
Takt Time Controller
Specify the station number with the rotary switch.
Setting range: 0 to 15
Available Device Memory
The available setting range of device memory varies depending on the model. Be sure to set within the range available for the
model to be used. Use [TYPE] when assigning indirect device memory for macro programs.
PLC_CTL
Macro command “PLC_CTL F0 F1 F2”
Item Setting Remarks
Connection Mode
1 : 1 / 1 : n
/ Multi-link2
Multi-link2 (Ethernet) /
1 : n Multi-link2 (Ethernet)
Signal Level RS-422/485
Baud Rate 115200 bps
Data Length 8 bits
Stop Bit 1 bit
Parity Odd
Target Port No. 0 to 15
Device Memory TYPE Remarks
P(parameter) 00H
Contents F0 F1 (=$u n) F2
Writing of parameter
(Flash ROM)
1 - 8
(PLC1 - 8)
nStation number
2
n + 1 Command: 1
Opening adjustment
*1
1 - 8
(PLC1 - 8)
nStation number
5
n + 1 Command: 2
n + 2
Port on the iB-Flow unit
1: A side
2: B side
3: Both A and B sides
n + 3
Pulse sending speed
10: Normally
20: When moving to home position
n + 4
Send pulse count
*2
0 - 9000, -12000 (home return)
Acquire operation time
*3
1 - 8
(PLC1 - 8)
nStation number
3
n + 1 Command: 3
n + 2
Operation time to acquire
11: Operation 1 (A to B operation)
12: Operation 2 (B to A operation)
n + 3 Operation time (unit: 10 msec)
Start measurement
1 - 8
(PLC1 - 8)
nStation number
2
n + 1 Command: 4
Switching offset status
*4
1 - 8
(PLC1 - 8)
nStation number
3
n + 1 Command: 5
n + 2
0: Invalid
1: Valid