2.1 Temperature Controller/Servo/Inverter Connection 2-15
2.1.3 ROBO CYLINDER (RCS/E-CON)
Communication Setting
Editor
Communication setting
(Underlined setting: default)
ROBO CYLINDER
RCS
Application software
Set parameters using the application software.
(Underlined setting: default)
RCS axis number setting switch
When changing the switch setting, turn the power off.
PORT switch (PORT)
Item Setting Remarks
Connection Mode
1 : 1 / 1 : n
/ Multi-link2 /
Multi-link2 (Ethernet) /
1 : n Multi-link2 (Ethernet)
Signal Level RS-232C
/ RS-422/485
Baud Rate 9600 / 19200 / 38400
/ 57600 / 115K bps
Data Length 8 bits
Stop Bit 1 bit
Parity None
Target Port No. 0 to 15
Parameter No. Parameter Name Setting
Parameter 16 SIO baud rate 9600 / 19200 / 38400
/ 58600 / 115200 bps
SW Setting Remarks
RCS-C: SW1
RCS-E: SW (switch No. 1 to 4)
Axis
number
Switch number
Always turn the switches 5
and 6 of RCS-E.
1 2 3 4
0
OFF OFF OFF OFF
1 ON OFF OFF OFF
2 OFF ON OFF OFF
3ONONOFFOFF
4OFFOFFONOFF
5 ON OFF ON OFF
6 OFF ON ON OFF
7ONONONOFF
8OFFOFFOFFON
9ONOFFOFFON
10 OFF ON OFF ON
11 ON ON OFF ON
12 OFF OFF ON ON
13 ON OFF ON ON
14 OFF ON ON ON
15 ON ON ON ON
PORT Setting Remarks
ON
SW
1
ON
1
2
3
4
SW
ON
1
2
3
4
5
6
PORT
ON
OFF