EasyManua.ls Logo

Fuji Electric Monitouch V9 Series - Lp-400 Series

Fuji Electric Monitouch V9 Series
482 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15.2 Temperature Controller/Servo/Inverter Connection 15-27
15.2.1 LP-400 Series
Communication Setting
Editor
Communication setting
(Underlined setting: default)
Laser Marker
Parameter
Set communication parameters using the console. For more information, refer to the instruction manual for the laser marker
issued by the manufacturer.
(Underlined setting: default)
DIP switch
* Keep the power off when changing the DIP switch setting.
* For communications with the V series, be sure to switch to the remote mode.
Item Setting Remarks
Connection Mode 1:1
/ Multi-link2 / Multi-link2 (Ethernet)
Signal Level RS-232C
Baud Rate 4800 / 9600 / 19200 / 38400 bps
Data Length 8 bits
Stop Bit 1 / 2 bits
Parity None
/ Odd / Even
Sum Check Provided / Not provided
CR/LF CR / CR/LF
Mode Sub Menu Item Setting Remarks
Environment
setting
Communication I/O
Baud Rate 4800 / 9600
/ 19200 / 38400 bps
Data Length 8 bit
Parity None / Odd / Even
Stop Bits 1
/ 2 bit
Delimit CR
/ CR+LF
Check Sum None
/ Provided
DPS-8
SW
No.
Contents Setting Remarks
1System reserve OFF: System reserved
2 External control method ON: RS-232C control
3
Buzzer at an occurrence
of error
ON: Not sound
OFF: Sound
4Password lock
ON: Password lock invalid
OFF: Password lock valid
5
Method to switch to
remote mode
6
7System reserve OFF: System reserved
8System reserve OFF: System reserved
ON
12345678
DPS-8
SW5 SW6 Operation
OFF OFF
Pressing the remote button on
the front of the controller
ON OFF
Inputting “REMOTE IN” on the
terminal block
OFF ON Turning the key switch ON