7.1 PLC Connection 7-19
When Connected at MJ1/MJ2:
RS-232C
Wiring diagram 1 - M2
Wiring diagram 2 - M2
Wiring diagram 3 - M2
Wiring diagram 4 - M2
PLC
RXD
RTS
SG
CTS
TXD 2
No.
3
4
5
7
Name
Dsub 25 (Male)
1
14
13
25
Name
No.
RJ - 45
7
8
5
RD
SD
SG
FG
MJ1/2
12345678
* Use shielded twist-pair cables.
PLC
RXD
RTS
SG
CTS
TXD 2
No.
3
4
5
7
Name
High density
Dsub 15 (Male)
5
15
1
11
10
Name
No.
RJ - 45
7
8
5
RD
SD
SG
FG
MJ1/2
12345678
* Use shielded twist-pair cables.
PLC
RXD
TXD
SG 1
No.
3
4
Name
RJ12
123456
Name
No.
RJ - 45
7
8
5
RD
SD
SG
FG
MJ1/2
12345678
* Use shielded twist-pair cables.
PLC
RXD
SG
TXD 2
No.
3
13
Name
Dsub 15 (Male)
8
15
1
9
Name
No.
RJ - 45
7
8
5
RD
SD
SG
FG
MJ1/2
12345678
* Use shielded twist-pair cables.