8-4 8. LS
Cnet Frame Editor
(Underlined setting: default)
Available Device Memory
The available setting range of device memory varies depending on the PLC model. Be sure to set within the range available for
the PLC to be used. Use [TYPE] when assigning indirect device memory for macro programs.
Item Setting Remarks
Channel RS232C
/ RS422
Baud Rate 9600 / 19200 / 38400
/ 76800 bps 76800: Valid only when [Channel: RS422 side] is selected
Data Bit 7 / 8
bits
Stop Bit 1
/ 2 bits
Parity None
/ Odd / Even
Station 0
to 31
Type RS422
/ RS485 To be set only when [Channel: RS422 side] is selected
Device Memory TYPE Remarks
P (input/output relay) 00H PW as word device, input relay: read only
M (auxiliary relay) 01H MW as word device
L (link relay) 02H LW as word device
K (keep relay) 03H KW as word device
F (special relay) 04H FW as word device, read only
T (timer/current value) 05H
C (counter/current value) 06H
D(data register) 07H
TC (timer/contact) 09H
CC (counter/contact) 0AH