9.2 Temperature Controller/Servo/Inverter Connection 9-73
*1 RS-485 communication is possible. Note that a communication fault (E.PUE) occurs as soon as the inverter is switched to the operation
mode with command source.
*2 When the value in the range from 0.1 to 999.8 is set:
If the V series does not start communication within the preset time, the inverter stops due to an alarm. This can be avoided by the
periodical reading setting.
*3 When the inverter is turned on with the settings of Pr.79=0/2/6 and Pr.340=1, the inverter enters in the Network operation mode.
*4 Operation mode can be changed between the PU operation mode and Network operation mode from the operation panel.
Available Device Memory
The available setting range of device memory varies depending on the model. Be sure to set within the range available for the
model to be used. Use [TYPE] when assigning indirect device memory for macro programs.
D (Parameter)
Device Memory TYPE Remarks
P (parameter) 00H Refer to the list file or the parameter list for the inverter.
D (parameter) 01H Refer to the table below.
Address Name
D0 Operation mode
0000 H: Network operation
0001 H: External operation
0002 H: PU operation
D1
Pr.37=0 : Frequency display, setting
Pr.370Machine speed at 60 Hz
D2 Output current
D3 Output voltage
D4 Fault description (First fault in past / Latest fault)
D5 Fault description (Third fault in past / Second fault in past)
D6 Fault description (Fifth fault in past / Fourth fault in past)
D7 Fault description (Seventh fault in past / Sixth fault in past)
D8
Inverter status monitor
* Definitions change according to the Pr.190 to 192.
D9 Second parameter changing
D10 Special monitor
D11
Special monitor selection No.
*1 Input terminal status
*2 Output terminal status
*3 Refer to the manual of the inverter.
Data Contents Unit Data Contents Unit
H01 Output frequency / speed
0.01 Hz
/ 0.001
H10
Output terminal status
*2
-
H02 Output current 0.01 A H14 Cumulative energization time 1 h
H03 Output voltage 0.1V H17 Actual operating time 1 h
H05 Frequency setting / speed setting
0.01 HZ
/ 0.001
H18 Motor load factor 0.1%
H07 Motor torque 0.1 % H19 Cumulative power 1 kWh
H08 Converter output voltage 0.1 V H34 PID set point 0.1 %
H09 Regenerative brake duty 0.1 % H35 PID measured value 0.1 %
H0A
Electric thermal relay function load
factor
0.1 % H36 PID deviation 0.1 %
H0B Output current peak value 0.01 A H3A
Option input terminal status1
*3
-
H0C
Converter output voltage peak
value
0.1 V H3B
Option input terminal status2
*3
-
H0E Output power 0.01 kW H3C
Option output terminal status
*3
-
H0F
Input terminal status
*1
-