15.2 Temperature Controller/Servo/Inverter Connection 15-31
CDC (logo condition)
FST (file setting)
WDC (print line width correction)
Address Name Setting Range
0000
Logo number 0
Area number 0 to F (HEX)
0001 X magnification 10000 to 1000000: 10.000 to 1000.000%
0002 Y magnification 10000 to 1000000: 10.000 to 1000.000%
0003 X position -300000 to +300000: -300.000 to +300.000 mm
0004 Y position -300000 to +300000: -300.000 to +300.000 mm
0005 Rotation angle -18000 to +18000: -180.00 to +180.00
0006 Laser power offset 0 to 200%
0007 Scan speed correction 5 to 500%
0100
Logo number 1
Area number 0 to F (HEX)
0101 X magnification 10000 to 1000000: 10.000 to 1000.000%
0102 Y magnification 10000 to 1000000: 10.000 to 1000.000%
0103 X position -300000 to +300000: -300.000 to +300.000 mm
0104 Y position -300000 to +300000: -300.000 to +300.000 mm
0105 Rotation angle -18000 to +18000: -180.00 to +180.00
0106 Laser power offset 0 to 200%
0107 Scan speed correction 5 to 500%
: : : :
1500
Logo number 15
Area number 0 to F (HEX)
1501 X magnification 10000 to 1000000: 10.000 to 1000.000%
1502 Y magnification 10000 to 1000000: 10.000 to 1000.000%
1503 X position -300000 to +300000: -300.000 to +300.000 mm
1504 Y position -300000 to +300000: -300.000 to +300.000 mm
1505 Rotation angle -18000 to +18000: -180.00 to +180.00
1506 Laser power offset 0 to 200%
1507 Scan speed correction 5 to 500%
Address Name Setting Range
0000 Laser power (LPW) 0005 to 1000: 000.5 to 100.0 (0.5 increments)
0001 Scan speed (SSP)
LP-430U/430TU/435U/435TU/420S9U/420S9TU/425S9U/
425S9TU/410U/410TU
00001 to 12000 mm/s
LP-431U/431TU/421S9U/421S9TU/411U/411TU
00001 to 06000 mm/s
0002 Frequency (MPL)
0: 5 kHz
1: 10 kHz
2: 20 kHz
0003 Print interval (INT) 00000 to 30000: 0000.0 to 3000.0 mm
0004 Line speed (LSP)
LP-430U/430TU/420S9U/420S9TU/425S9U/425S9TU/
435U/435TU
60 to 240000: 000.060 to 240.000 m/min
LP-431U/431TU/421S9U/421S9TU
60 to 120000: 000.060 to 120.000 m/min
LP-410U/410TU
60 to 170000: 000.060 to 170.000 m/min
LP-411U/411TU
60 to 85000: 000.060 to 085.000 m/min
0005 Encoder pulse (ENC) 00500 to 60000: 005.00 to 600.00 pulse/mm
Address Name Setting Range
0000 Print line width correction 0010 to 2000: 0.010 to 2.000 mm
0001 Filling interval 0010 to 2000: 0.010 to 2.000 mm