15.2 Temperature Controller/Servo/Inverter Connection 15-35
PLC_CTL
Macro command “PLC_CTL F0 F1 F2
*1 When “-1” is set for both start of period and end of period, the reading period is set as undefined.
*2 When writing is executed while “-1” is set for both start of period and end of period, the setting is deleted.
Contents F0 F1 (= $u n) F2
File overwrite
1 - 8
(PLC1 - 8)
n Station number: 0 (fixed)
2
n + 1 Command: A1H
File registration
1 - 8
(PLC1 - 8)
n Station number: 0 (fixed)
3
n + 1 Command: A2H
n + 2
File
number
LP-430U/430TU/431U/431TU
0 to 1023
LP-435U/435TU/425S9U/425S9TU/
420S9U/420S9TU/410U/410TU/
421S9U/421S9TU/411U/411TU
0 to 2047
Reading of lot text
1 - 8
(PLC1 - 8)
n Station number: 0 (fixed)
4
n + 1 Command: 23H
n + 2 Lot number: 0 to 7
n + 3 Period number
n + 4 to n + 5
Start of period
*1
n + 6 to n + 7
End of period
*1
n + 8 to n + 16 Set text
Lot text setting
1 - 8
(PLC1 - 8)
n Station number: 0 (fixed)
8 + number
of words of
set text
(max. 9
words)
n + 1 Command: A3H
n + 2 Lot number: 0 to 7
n + 3 Period number
n + 4 to n + 5
Start of period
*2
n + 6 to n + 7
End of period
*2
n + 8 to n + 16 Set text
Reading of
step & repeat
setting
Setting delete
1 - 8
(PLC1 - 8)
n Station number: 0 (fixed)
3
n + 1 Command: 24H
n + 2 List line: 00 to 99
n + 3 Fine-adjustment type: 0 (setting delete)
Single
fine-adjustment
1 - 8
(PLC1 - 8)
n Station number: 0 (fixed)
3
n + 1 Command: 24H
n + 2 List line: 00 to 99
n + 3 Fine-adjustment type: 1 (single adjustment)
n + 4 Target line: 001 to 100
n + 5 Target column: 001 to 100
n + 6 to n + 7
X-axis
adjustment
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
-55000 to +55000:
-055.000 to +055.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
-27500 to +27500:
-027.500 to +027.500 mm
LP-435U/435TU/425S9U/425S9TU
-80000 to +80000:
-080.000 to +080.000 mm
n + 8 to n + 9
Y-axis
adjustment
Print OFF
1 - 8
(PLC1 - 8)
n Station number: 0 (fixed)
3
n + 1 Command: 24H
n + 2 List line: 00 to 99
n + 3 Fine-adjustment type: 2 (print OFF)
n + 4 Target line: 001 to 100
n + 5 Target column: 001 to 100