15-42 15. Panasonic
Writing of text
condition
Arc-shaped
printing
1 - 8
(PLC1 - 8)
n Station number: 0 (fixed)
26
n + 1 Command: A5H
n + 2 Condition number: 01 to 60
n + 3 Area number: 0 to F (HEX)
n + 4 Start line: 01 to 60
n + 5 End line: 01 to 60
n + 6
Standard character arrangement
3: Printing out of the arc (clockwise)
4: Printing inside the arc (counterclockwise)
n + 7
Text origin
0: Left end
1: Center
2: Right end
n + 8 to n + 9
Character
height
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
200 to 110000:
000.200 to 110.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
200 to 55000:
000.200 to 055.000 mm
LP-435U/435TU/425S9U/425S9TU
200 to 160000:
000.200 to 160.000 mm
n + 10 to n + 11
Character
width
n + 12 to n + 13
Center position X
-300000 to +300000: -300.000 to +300.000 mm
n + 14 to n + 15
Center position Y
-300000 to +300000: -300.000 to +300.000 mm
n + 16 to n + 17
Radius
0 to +300000: 000.000 to +300.000 mm
n + 18 to n + 19
Radius of
spaces
between
lines
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
0 to 110000:
000.000 to 110.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
0 to 55000:
000.000 to 055.000 mm
LP-435U/435TU/425S9U/425S9TU
000 to 160000:
000.000 to 160.000 mm
n + 20
Start angle
-18000 to +18000: -180.00 to +180.00
n + 21
Angle of spaces between characters
-18000 to +18000: -180.00 to +180.00
n + 22
Font designation
1: Character font 1
2: Character font 2
n + 23
Line width
of bold
character
LP-430U/430TU/435U/435TU/420S9U/
420S9TU/425S9U/425S9TU/410U/
410TU
0 to 6000: 0.000 to 6.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
0 to 4000: 0.000 to 4.000 mm
n + 24 Laser power offset: 000 to 200%
n + 25 Scan speed correction: 005 to 500%
Contents F0 F1 (= $u n) F2