15-44 15. Panasonic
Step & repeat
condition
Writing of
condition
1 - 8
(PLC1 - 8)
n Station number: 0 (fixed)
10
n + 1 Command: AAH
n + 2
Step & repeat
0: None
1: Provided
n + 3 Number of lines: 001 to 100
n + 4 Number of columns: 001 to 100
n + 5 to n + 6 Line step
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
0 to 110000:
000.000 to 110.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
0 to 55000:
000.000 to 055.000 mm
LP-435U/435TU/425S9U/425S9TU
000 to 160000:
000.000 to 160.000 mm
n + 7 to n + 8
Column
step
n + 9
Counter motion
0000H: Same for all steps
001xH: Unallocated number
002xH: Serial number
00x0H: From top left toward right
00x1H: From top left toward bottom
00x2H: From top right toward left
00x3H: From top right toward bottom
Text condition
(abbreviated
form)
Reading of text
condition
(abbreviated
form)
1 - 8
(PLC1 - 8)
n Station number: 0 (fixed)
3
n + 1 Command: 2BH
n + 2 Condition number (01 to 60)
n + 3 to n + 4 X position
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
-55000 to +55000:
-055.000 to +055.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
-27500 to +27500:
-027.500 to +027.500 mm
LP-435U/435TU/425S9U/425S9TU
-80000 to +80000:
-080.000 to +080.000 mm
n + 5 to n + 6 Y position
n + 6 to n + 7 Laser power offset: 000 to 200%
Writing of text
condition
(abbreviated
form)
1 - 8
(PLC1 - 8)
n Station number: 0 (fixed)
8
n + 1 Command: ABH
n + 2 Condition number (01 to 60)
n + 3 to n + 4 X position
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
-55000 to +55000:
-055.000 to +055.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
-27500 to +27500:
-027.500 to +027.500 mm
LP-435U/435TU/425S9U/425S9TU
-80000 to +80000:
-080.000 to +080.000 mm
n + 5 to n + 6 Y position
n + 6 to n + 7 Laser power offset: 000 to 200%
Contents F0 F1 (= $u n) F2