15.2 Temperature Controller/Servo/Inverter Connection 15-49
Reading of
barcode print
condition
RSS-14 Expanded
Stacked
1 to 8
(PLC1 to 8)
n Station number: 0 (fixed)
3
n+1 Command: 2CH
n+2 Barcode number: 0 to 7
n+3 Area number: 0 to FH
n+4
Type
35: RSS Expanded Stacked
45: RSS Expanded Stacked CC-A
55: RSS Expanded Stacked CC-B
n+5
Human-readable string
0: Without human-readable string
2: With human-readable string
n+6
Inversion
0: Invalid
1: Valid
2: Valid (with guard pattern)
n+7 to n+8
Barcode
1-stack
height
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
001000 to 110000: 001.000 to
110.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
001000 to 055000: 001.000 to
055.000 mm
LP-435U/435TU/425S9U/425S9TU
001000 to 160000: 001.000 to
160.000 mm
n+9
Separator height (W) ratio
000 to 100: 00.0 to 10.0 mm
n+10
Number of horizontal symbol characters: 2 to 20
(even)
n+11
Standard module width
0050 to 1000: 0.050 to 1.000 mm
n+12 to n+13 X position
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
-55000 to +55000: -055.000 to
+055.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
-27500 to +27500: -027.500 to
+027.500 mm
LP-435U/435TU/425S9U/425S9TU
-80000 to +80000: -080.000 to
+080.000 mm
n+14 to n+15 Y position
n+16 to n+17
Tilting angle
-18000 to +18000: -180.00 to +180.00 deg
n+18 Laser power correction: 0 to 200%
n+19 Scan speed correction: 5 to 500%
Composite
1 to 8
(PLC1 to 8)
n Station number: 0 (fixed)
3
n+1 Command: 2CH
n+2 Barcode number: 0 to 7
n+3 Area number: 0 to FH
n+4
Type
CC-A composite
46: JAN/UPC
47: UCC/EAN128
48: JAN/UPC with 1D human-readable string
49: UCC/EAN128 with 1D human-readable string
CC-B composite
56: JAN/UPC
57: UCC/EAN128
58: JAN/UPC with 1D human-readable string
59: UCC/EAN128 with 1D human-readable string
CC-C composite
67: UCC/EAN128
69: UCC/EAN128 with 1D human-readable string
n+5
Human-readable string
0: Without human-readable string
2: With human-readable string
n+6
Inversion
0: Invalid
1: Valid
Contents F0 F1 (= $u n) F2