15.2 Temperature Controller/Servo/Inverter Connection 15-51
Writing of
barcode print
condition
Data matrix code
(ECC200)
1 to 8
(PLC1 to 8)
n Station number: 0 (fixed)
16
n+1 Command: ACH
n+2 Barcode number: 0 to 7
n+3 Area number: 0 to FH
n+4
Type
20: Data matrix
n+5
Data input mode
0: 1-byte
1: Kanji characters
n+6 Number of rows
n+7 Number of columns
n+8 to n+9 X position
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
-55000 to +55000:
-055.000 to +055.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
-27500 to +27500:
-027.500 to +027.500 mm
LP-435U/435TU/425S9U/425S9TU
-80000 to +80000:
-080.000 to +080.000 mm
n+10 to n+11 Y position
n+12 to n+13
Rotation angle
-18000 to +18000: -180.00 to +180.00 deg
n+14
Module pitch: vertical
0050 to 1000: 0.050 to 1.000 mm
n+15
Module pitch: horizontal
0050 to 1000: 0.050 to 1.000 mm
CODE39
ITF
NW-7
1 to 8
(PLC1 to 8)
n Station number: 0 (fixed)
20
n+1 Command: ACH
n+2 Barcode number: 0 to 7
n+3 Area number: 0 to FH
n+4
Type
00: CODE39
01: ITF
03: NW-7
n+5
Inversion
0: Invalid
1: Valid
n+6
Check character
CODE39, ITF
0: No
1: Yes
NW-7
A to D: Without check character
a to d: With check character
n+7 to n+8 Height
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
001000 to 110000:
001.000 to 110.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
001000 to 055000:
001.000 to 055.000 mm
LP-435U/435TU/425S9U/425S9TU
001000 to 160000:
001.000 to 160.000 mm
n+9
Narrow element width
0050 to 1000: 0.050 to 1.000 mm
n+10 to n+11 X position
LP-430U/430TU/420S9U/420S9TU/
410U/410TU
-55000 to +55000:
-055.000 to +055.000 mm
LP-431U/431TU/421S9U/421S9TU/
411U/411TU
-27500 to +27500:
-027.500 to +027.500 mm
LP-435U/435TU/425S9U/425S9TU
-80000 to +80000:
-080.000 to +080.000 mm
n+12 to n+13 Y position
Contents F0 F1 (= $u n) F2