16.1 Temperature Controller/Servo/Inverter Connection 16-1
16.1 Temperature Controller/Servo/Inverter Connection
Serial Connection
Module-type Temperature Controller
*1 Select a model on which Modbus communication is available.
“2: Modbus” for the communication protocol is selectable in the initial setting code when “specify quick start code 1 and 2” is selected as
the quick start code.
Single Loop Temperature Controller
PLC Selection on the
Editor
Model Port
Signal
Level
Connection
Lst File
CN1 MJ1/MJ2
SR-Mini
(MODBUS RTU)
H-PCP-A-x4N-4 * xx Z-1021
Modular
connector 1/2
RS-422A Wiring diagram 2 - C4 Wiring diagram 2 - M4 SR-Mini.Lst
H-PCP-B-x4N-4 * xx Z-1021
SR-Mini
(Standard Protocol)
H-PCP-A-x4N-4 * xx
Modular
connector 1/2
RS-422A Wiring diagram 2 - C4 Wiring diagram 2 - M4 RKC_Std.Lst
H-PCP-B-x4N-4 * xx
SRV
(MODBUS RTU)
V-TIO-A-xxxxx-xx*xxx-xx-x-6
Communication
terminal
RS-485
(2-wire
system)
Wiring diagram 1 - C4 Wiring diagram 1 - M4 RKC_SRV.Lst
V-TIO-C-xxxxx-xx*xxx-xx-x-6
SRZ
(MODBUS RTU)
Z-TIO-A-x-xxxx/x2-x xxx/Y
*1
Communication
terminal
RS-485
(2-wire
system)
Wiring diagram 1 - C4 Wiring diagram 1 - M4
RKC_SRZ_
TIO.Lst
Z-TIO-B-x-xx/xN2-xxxx/Y
*1
Z-DIO-A-x-xx/x-xxx2
RKC_SRZ_
DIO.Lst
PLC Selection on the
Editor
Model Port
Signal
Level
Connection
Lst File
CN1 MJ1/MJ2
CB100/CB400/
CB500/CB700/
CB900
(MODBUS RTU)
CB100xxxx-xx*xx-5x/x
Z-1021
Communication
terminal
RS-485 Wiring diagram 1 - C4 Wiring diagram 1 - M4 CB100.Lst
CB400xxxx-xx*xx-5x/x
Z-1021
CB500xxxx-xx*xx-5x/x
Z-1021
CB700xxxx-xx*xx-5x/x
Z-1021
CB900xxxx-xx*xx-5x/x
Z-1021
REX-F400/F700/
F900
(Standard Protocol)
F400xxxx-xx*xx-xxx-1x
F700xxxx-xx*xx-xxx-1x
F900xxxx-xx*xx-xxx-1x
Communication
terminal
RS-232C Wiring diagram 1 - C2 Wiring diagram 1 - M2
RKC_F400.Lst
F400xxxx-xx*xx-xxx-4x
F700xxxx-xx*xx-xxx-4x
F900xxxx-xx*xx-xxx-4x
Communication
terminal
RS-422A Wiring diagram 3 - C4 Wiring diagram 3 - M4
F400xxxx-xx*xx-xxx-5x
F700xxxx-xx*xx-xxx-5x
F900xxxx-xx*xx-xxx-5x
Communication
terminal
RS-485 Wiring diagram 1 - C4 Wiring diagram 1 - M4
FB100/FB400/
FB900
(MODBUS RTU)
FB400-xx-x*xxx1/xx-xxxx
FB400-xx-x*xxxW/xx-xxxx
FB900-xx-x*xxx1/xx-xxxx
FB900-xx-x*xxxW/xx-xxxx
Communication
terminal
RS-232C Wiring diagram 1 - C2 Wiring diagram 1 - M2
RKC_FB.Lst
FB400-xx-x*xxx4/xx-xxxx
FB900-xx-x*xxx4/xx-xxxx
Communication
terminal
RS-422A Wiring diagram 3 - C4 Wiring diagram 3 - M4
FB100-xx-x*E/xx-xxxx
FB100-xx-x*F/xx-xxxx
FB100-xx-x*G/xx-xxxx
FB100-xx-x*H/xx-xxxx
FB100-xx-x*J/xx-xxxx
FB400-xx-x*xxx5/xx-xxxx
FB400-xx-x*xxxW/xx-xxxx
FB400-xx-x*xxxX/xx-xxxx
FB400-xx-x*xxxY/xx-xxxx
FB900-xx-x*xxx5/xx-xxxx
FB900-xx-x*xxxW/xx-xxxx
FB900-xx-x*xxxX/xx-xxxx
FB900-xx-x*xxxY/xx-xxxx
Communication
terminal
RS-485 Wiring diagram 1 - C4 Wiring diagram 1 - M4

Table of Contents