Technical data
Technical data
Electrical data
Safety standards complied with: IEC 60 950-1, EN 60950-1, U L 60950
CSA 22.2 No.60950-1
Protection class: I
Rated voltage range 100 V – 240 V
Rated frequency
50 Hz – 60 Hz
Max. rated current
CELSIUS R940 (1000 W), 100 V – 240 V
CELSIUS R940power (1300 W), 100 V – 240 V
12.0 A - 5.0 A
12.0 A - 6.0 A
Dimensions
Width/depth/height: 186 mm x 618 mm x 430 mm /7.32 inch x 24.33
inch x 16.93 inch
Weight
in basic configuration: approx. 22 kg / 48.5 lbs
Ambient conditions
Environment class 3K2
Environment class 2K2
DIN IEC 721 part 3-3
DIN IEC 721 part 3-2
Temperature
Operation (3K2) 10 °C .... 35 °C /50 °F ... 95 °F
Transportation (2 K 2) –25 °C .... 60 °C /–13 °F ... 1 40 °F
The formation of co ndensation is not permitted while the device is in operation !
Clearance required to e nsure adequate ventilation:
without air vents
with air vents
min. 10 mm / 0.39 inches
min. 200 mm / 7.87 inches
The data sheets for these devices contain further technical data. The data sheets
can be found on our website at "
http://www.fujitsu.com/fts".
Fujitsu 79