EasyManua.ls Logo

Fujitsu ETERNUS DX60 S3 - Page 66

Fujitsu ETERNUS DX60 S3
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
If the network environment is set with the factory default, some functions are not available.
Make sure to set up the network environment.
Do not use the RMT port for an operation management LAN. Use the RMT port only for remote sup-
port.
Configure the IP address for the MNT port with an IP address in a different subnetwork than the
RMT port.
When specifying the IP address of the Slave CM, specify an IP address that is in the same subnet
but is different from the IP address of the Master CM.
Either or both an IPv4 address and an IPv6 address can be specified for the MNT port and the RMT
port.
(1) Click the [IPv4 Settings] tab to specify an IPv4 address. Click the [IPv6 Settings] tab to specify an
IPv6 address.
The following procedure shows an example when selecting the [IPv4 Settings] tab.
A confirmation screen appears.
(2) Click the [OK] button.
The network environment setting is applied and the setting completion screen appears.
(3) Click the [Finish] button.
The [Logout] screen appears.
Chapter 5 General Settings
5.4 Storage Management (Initial Setup 1)
66
FUJITSU Storage ETERNUS DX60 S3 Disk storage system
Configuration Guide (Basic)
Copyright 2014 FUJITSU LIMITED
P3AM-9002-01ENZ0

Table of Contents

Other manuals for Fujitsu ETERNUS DX60 S3

Related product manuals