EasyManua.ls Logo

Fujitsu M2488 - 2-6.3 Cable and Power Connections; Figure 2-2. Cable and Power Connections

Fujitsu M2488
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M2488 USER’S GUIDE INSTALLATION INSTRUCTIONS
April 1997 CG00000-011403 REV. A 2-7
2-6.3 Cable and Power Connections
Installation of the SCSI cables and power cord are described in the following paragraphs. A descrip-
tion of the SCSI connectors follows the installation procedure.
** NOTE **
1. Cable and power connections should only be made upon comple-
tion of the M2488 hardware setup to include attachment of optional
equipment. Use the appropriate assembly procedures for the desired
option.
2. Both SCSI connectors on the IPM must be connected. The con-
nection may be either two SCSI cables or one SCSI cable and one
Terminator.
See Figure 2-2
.
Figure 2-2. Cable and Power Connections
STEP ACTION
1 Attach SCSI cable to one of the SCSI connectors on the IPM (either connector will work).
2 Attach the Terminator or second SCSI cable to the other SCSI connector on the IPM.
3 Connect power cord.