INSTALLATION INSTRUCTIONS M2488 USER’S GUIDE
2-10 CG00000-011403 REV. A April 1997
Table 2-4. Differential, 50 pin Contact Assignments
SIGNAL NAME
CONNECTOR
CONTACT
NUMBER
CABLE
CONDUCTOR
NUMBER
CABLE
CONDUCTOR
NUMBER
CONNECTOR
CONTACT
NUMBER
SIGNAL NAME
ground 1 1 2 26 ground
+DB(0) 2 3 4 27 -DB(0)
+DB(1) 3 5 6 28 -DB(1)
+DB(2) 4 7 8 29 -DB(2)
+DB(3) 5 9 10 30 -DB(3)
+DB(4) 6 11 12 31 -DB(4)
+DB(5) 7 13 14 32 -DB(5)
+DB(6) 8 15 16 33 -DB(6)
+DB(7) 9 17 18 34 -DB(7)
+DB(P) 10 19 20 35 -DB(P)
DIFFSENS 11 21 22 36 ground
reserved 12 23 24 37 reserved
TERMPWR 13 25 26 38 TERMPWR
reserved 14 27 28 39 reserved
+ATN 15 29 30 40 -ATN
ground 16 31 32 41 ground
+BSY 17 33 34 42 -BSY
+ACK 18 35 36 43 -ACK
+RST 19 37 38 44 -RST
+MSG 20 39 40 45 -MSG
+SEL 21 41 42 46 -SEL
+C/D 22 43 44 47 -C/D
+REQ 23 45 46 48 -REQ
+I/O 24 47 48 49 -I/O
ground 25 49 50 50 ground