CONFIGURATION M2488 USER’S GUIDE
4-12 CG00000-011403 REV. A April 1997
a. If there is an outstanding SCSI command or if there is a tape loaded in the tape drive then Off-line
mode cannot be entered.
Step 2. Press the START push-button until INQUIRY is displayed. The information available is
described in Table 4-10.
Step 3. Press the TEST pushbutton.
Step 4. The first item, REV LEVL, is displayed. Press TEST to view the vendor information or
START to view next option.
Table 4-10. Information Description
OPTION DESCRIPTION
REV LEVL
Microcode revision level: example
REV=” 1. A.13”
IPM TYPE Type of Interface Personality Module installed.
Example:
IPM=”SINGLE-ENDED, 50 PIN”
TAPEUNIT Select sub-menu to modify Tape unit Vital Product Data pages (sub-
menu described in Table 4-11)
MED-CHGR Select sub-menu to modify Medium-Changer Vital Product Data
pages (sub-menu described in Table 4-12)
Table 4-11. Tape Unit VPD Pages Menu
OPTION DESCRIPTION
PAGE C2 Modify Tape-Unit Vital Product Data page C2 (sub-menu described
in Table 4-13)
Table 4-12. Medium-Changer VPD Pages Menu
OPTION DESCRIPTION
PAGE C2 Modify Medium-Changer Vital Product Data page C2 (sub-menu
described in Table 4-13)
Table 4-13. Settable VPD Page C2 Menu
OPTION SETTINGS DESCRIPTION
DEFAULT
SETTINGS
VENDOR V=”” Vendor ID, 8 ASCII characters
CTLR PID CPID=”” Controller Product ID, 8 ASCII characters
LUN PID LPID=”” Log Unit Product ID, 8 ASCII characters
PGC2:WTR WTROM: Y
N
If Y, the setting data is written to nonvolatile memory.
If N, the setting data is not written to nonvolatile memory.
Y