M2488 USER’S GUIDE CONFIGURATION
April 1997 CG00000-011403 REV. A 4-11
4-4 DRIVE INFORMATION
Use the Inquiry menu to display or modify selected information about the M2488 configuration. An
explanation of this menu is given in Table 4-9.
Table 4-9. Operator Panel Top Level Menus - Information (Inquiry)
TEST
and
UNLOAD
pressed
TEST
and
UNLOAD
released
*
→
OFFLINE
→
DIAGMODE
Selection and execution of off-
line diagnostics
Product Guide
Section 8-4
↓
START
SETTING
Access and configure user
settable options
User’s Guide
Section 4-2
↓
START
LOADCODE
Copy new firmware from a code
image tape cartridge into non-
volatile memory of M2488.
User’s Guide
Section 4-3
↓
START
INQUIRY
TEST
→
View M2488 Information User’s Guide
Section 4-4
MODE PGS
Display or change selected Tape
Unit or Medium-Changer Mode
Pages
User’s Guide
Section 4-5
FACTORY
Change factory mode settings,
enable factory mode, or enable
factory diagnostics.
Product Guide
Section 8-5
Navigation keys:
To navigate through the options, settings, and to make changes from the Operator Panel:
Press
START
to move forward through the options or settings. It will also increment the settings
numbers.
Press
SHIFT
and
START
to move backward through the options or settings. It will also decrement
the settings numbers.
Press
RESET
to move from settings to option or to leave setting mode.
Press
TEST
to move from the option to settings.
Press
UNLOAD
to select a number field for multiple digit numbers.
Setting Procedure:
Step 1. Press and hold both the
TEST
and
UNLOAD
keys, wait for OFFLINE to be displayed then
release both keys.
a
Once the keys are released then the first item, DIAGMODE, in the
main Off-line menu will be displayed. (Keys must be held for approximately 2 seconds
before Off-line mode is entered.)