20 Operating Manual TX100 S3 Core Edition
Functional overview
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Noise level
Electrical values
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2) 10 °C ... 35 °C
Transport (2K2) -25 °C ... 60 °C
Humidity 10% ... 85% (non condensing)
Sound power level L
WAd
(ISO 9296) < tbd B (standby)
< tbd B (operation)
Sound pressure level at adjacent position
L
pAm
(ISO 9296)
< tbd dB (A) (standby)
< tbd dB (A) (operation)
Power supply configuration 1x standard power supply
Max. output 250 W
Rated voltage range 100 V - 240 V
Rated frequency range 50 Hz - 60 Hz
Rated current max. 4.0 A – 2.0 A (100 V / 240 V)
Power supply configuration 1x 0-Watt power supply
Max. output 250 W
Rated voltage range 100 V - 240 V
Rated frequency range 50 Hz - 60 Hz
Rated current max. 5.0 A – 2.5 A (100 V / 240 V)

Table of Contents

Other manuals for Fujitsu PRIMERGY TX100 S3 Core Edition

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX100 S3 Core Edition and is the answer not in the manual?

Fujitsu PRIMERGY TX100 S3 Core Edition Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY TX100 S3 Core Edition
CategoryServer
LanguageEnglish

Related product manuals