20 Operating Manual TX150 S6
Technical data Preface
Mechanical values
Weight
Approx. up to 28 kg (depending on configuration).
Ventilation clearance
At least 200 mm on the front and rear.
Ambient conditions
Condensation during operation must be avoided!
Noise level
Floorstand model Rack model
Width 205 mm 482 mm (front panel)
Total depth 605 mm 642 mm (with handles)
Installation depth ------- 607 mm
Height 444 mm (with feet) 221 mm / 5 HE
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature:
Operation (3K2) 10 °C ... 35 °C
Transport (2K2) -25 °C ... 60 °C
Humidity 10% ... 85%
Sound power level L
WAd
(ISO 9296) < 4.8 B (standby)
< 5.0 B (operation)
Sound pressure level at adjacent workstation
L
pAm
(ISO 9296)
< 29 dB (A) (standby)
< 31 dB (A) (operation)