42 Operating Manual TX150 S6
Mounting the rack model Hardware installation
For rack systems from other manufacturers:
3rd party rack
Certain general conditions must be met:
– Installation dimensions (see the dimensions shown in figure 4 on page 44).
– You must ensure that the safety mechanisms on the server, e.g. stoppers or
retaining systems, are functioning correctly.
– The shape of the rack support uprights must ensure that the telescopic rails
can be bolted at the front.
– Front bolted telescopic rails.
The rails have a linear alignment feature to ensure that they can be adjusted
to different rack depths.
– No cable management support (delivered with the mounting kit).
1 Front of rack
2 Rear of rack
A Rack depth (comparison PRIMECENTER rack 940/1000/1100 mm)
B Rack width (comparison PRIMECENTER rack 700 mm)
C Clearance for 19” installation level
C1 Front 19” installation level
C2 Rear 19” installation level
D Cable routing area (cable area depth) and ventilation
E Space for front panel and ventilation
F Space for right and left support systems
P PRIMERGY rack installation depth
a1 Front left support upright
a2 Front right support upright
b1 Rear left support upright
b2 Rear right support upright