Ê Reinstall the processor fan holder (see page 38).
Ê Reinstall the ventilation duct over the system fans (see page 39).
Ê Reinstall the ventilation duct over the main memory (see page 30).
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 97ff.
6.3 Replacing the heat sink
Ê Open the server as described in the chapter “Preparation” on page 19ff.
Ê Remove the ventilation duct over the main memory (see page 28).
Ê Remove the ventilation duct over the system fans (see page 32).
Ê Remove the heat sink (see page 33).
Ê Remove the processor fan holder (see page 35).
Ê Loosen the four screws on the heat sink socket in a crossover pattern (see
page 41).
Ê Loosen the heat sink by turning it back and forth and then lift it out.
Ê Clean the upper side of the processor using a lint-free cloth.
Ê Remove the protective cover from the new heat sink (see page 36).
Ê Place the heat sink on the processor socket (see page 37).
Ê Fasten the heat sink by tightening the four screws in a crossover pattern.
Ê Reinstall the processor fan holder (see page 38).
Ê Reinstall the ventilation duct over the system fans (see page 39).
Ê Reinstall the ventilation duct over the main memory (see page 30).
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter “Completion” on page 97ff.