EasyManua.ls Logo

Fungilab VISCOLED ADVANCE Series - ADVANCE L Special Heldal Spindle Selection Table; Guideline Values for Heldal Spindles (PA-PF)

Fungilab VISCOLED ADVANCE Series
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ADVANCE Manual
59/69
20. ADVANCE L special Heldal spindle selection table
Maximum guideline values in cP (mPa·s)
RPM/SP
PA
PB
PC
PD
PE
PF
0.3
62.4K
124.8K
312K
624K
1.5M
3.1M
0.5
37.4K
74.8K
187K
374K
936K
1.8M
0.6
31.2K
62.4K
156K
312K
780K
1M
1
18.72K
37.4K
93.6K
187K
468K
936K
1.5
12.4K
24.9K
62.4K
124K
312K
624K
2
9.36K
18.7K
46.8K
93.6K
234K
468K
2.5
7.4K
14.9K
37.4K
74.8K
187K
374.4K
3
6.2K
12.4K
31.2K
62.4K
156K
312K
4
4.6K
9.3K
23.4K
46.8K
117K
234K
5
3.7K
7.4K
18.7K
37.4K
93.6K
187.2K
6
3.1K
6.2K
15.6K
31.2K
78K
156K
10
1.8K
3.7K
9.3K
18.7K
46.8K
93.6K
12
1.5K
3.12K
7.8K
15.6K
39K
78K
Table 14.
ATTENTION:
K Indicates thousands. Example: 7.8K = 7800
M Indicates millions Example: 1.56M = 1560000
NOTE: It is not recommended to work with viscosity values of less than 15% of the lower part of the selected
scale.

Table of Contents