ADVANCE Manual
8/69
The viscometer is powered by a MEAN WELL GS25A12-P6J power supply. Do not open, expose,
modify or touch the internal circuitry of the power supply.
8. Equipment presentation
-
Once the equipment package is received, check and confirm the delivery
note. If some discrepancy or problem is found, notify immediately the
supplier.
-
Verify that the viscometer model corresponds to the one that was
ordered.
-
Read carefully the instruction manual.
-
The manufacturer is not responsible for any damages that may result from
modifications or lack of maintenance of any of the machine’s mechanisms
(directive 89/655/CEE).
Fungilab recommends using the carry-case provided with the equipment for
making any kind of delivery. Please, keep the carry-case in a safe location. In case
of transporting the equipment or during long storage periods, always place each
part of the equipment as shown in figure 1. It can be seen that the position of each
piece inside the equipment’s carry-case is presented. In case of an incorrect
packaging, the pieces of equipment can suffer some damage. This damage will not
be covered by Fungilab’s guarantee.
Parts included within the equipment standard delivery:
-
Viscometer head with serial number
-
Foot or base, 3 height adjustable knobs for the base
-
Nut
-
Fastening rod
-
Standard spindles
-
Spindle guard
-
Spindle support
-
Calibration Certificate
-
Conformity declaration
-
Oil certificate document copy
-
USB-Memory containing the User Manual (PDF file). The USB-Memory might contain also the
company catalogues.
-
Power cable
-
PT100 Temperature probe
-
Clip for holding the PT100 probe
-
MEAN WELL GST25A12-P1J power supply
Do not open the power supply due to electrical shock risk. There are not
serviceable parts inside. In case of suspecting of a power supply malfunction,
please contact FUNGILAB for assistance.
It is mandatory to leave enough free space around the equipment ON/OFF switch,
needs to be reachable at any time, especially in case of an emergency or
malfunction.
It is very important to treat the silkscreen printed logos carefully when cleaning
the equipment. Please use a soft cloth, with isopropyl alcohol (70%).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fungilab VISCOLED ADVANCE Series and is the answer not in the manual?

Fungilab VISCOLED ADVANCE Series Specifications

General IconGeneral
BrandFungilab
ModelVISCOLED ADVANCE Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals