REMOTE
I1-5
Equipment Port
Specification
(Default)
Option Note
REMOTE A RS-232C None
Connected RT
(Standard connection)
REMOTE B RS-232C None
Connected DSC
(Standard connection)
CIF/NMEA NMEA None
Select to Jumper setting in CONT
board and Terminal setting.
PRINTER Centronics None
Complies with Centronics
interface
DP-5
CONTROL RS-232C None Not use
REMOTE A RS-232C None Connected the Radiotelephone
REMOTE B RS-232C None Connected the DSC
IEC-1162
(NMEA)
IEC-1162 None
DP-6/10
PRINTER
(Connected IB-581)
Centronics None
Complies with Centronics
interface
MF.HF DSC C.Loop None
No.1 VHF C.Loop None
No.2 VHF C.Loop None
SES RS-410N None
EGC RS-410N None
NAVTEX RS-410N None Contact signal
DMC-5
2182kHz WR None AF signal
NMEA/CIF NMEA
Select to NMEA or CIF
(TB Board S1)
ALM BZ RS-410N
NX-500
ANT active
Select to WIRE or ACT
(TB Board S2)
RB-700 TB-1 C.Loop None
RB-500 TB-1 C.Loop None
For RT(FS-xxxx) ROM No.
0550147103
For XMIT(FT-503/803) ROM No.
0550160100
IN RS-232C None
OUT RS-232C None
OUT RS-232C None
DB-120
(05P0606)
NMEA NMEA None
REMOTE 1(IN)
C.Loop RS-232C
REMOTE 2(OUT)
C.Loop RS-232C
REMOTE 3(OUT)
C.Loop RS-232C
REMOTE 4(OUT)
Option
C.Loop or
RS-232C
DB-500
(Standard type)
Refer to page
I1-1.
REMOTE 5(OUT)
Option
C.Loop or
RS-232C
Select to the REMOTE-A or B
board.
- RS-232C:REMOTE A(05P0457)
- C.Loop:REMOTE B(05P0458)