112
6 Modifications to the basic vehicle
6.12 Handling of EV system
MITSUBISHI FUSO body/equipment mounting directives for FE Issue date: 20. 10. 2020
! Only print out complete sections from the current version
(c) High voltage shutoff procedure
• Perform the following steps. Copy the voltage
shutoff report on the next page, check all the
items, record the values, and store the report.
• Check the Duspol high voltage tester function
and appearance for abnormalities. Record the
Duspol high voltage tester inspection date.
• Be sure to wear insulation gloves for high
voltage.
• Lock the wheels and apply the parking brake.
• Put a sign of "High voltage vehicle. Danger: high
voltage" on the cab.
• Remove the starter key and store it in a safe
place.
• The charge connector is removed.
• Press in the high voltage shutoff switch.
• Inspect the high voltage related parts and check
the appearance of high voltage battery for
damages.
• Remove the protection cover and blind plug
from the high voltage battery 1.
• Securely connect to the blind plug socket
of the high voltage battery.
Other items to be prepared
Symbol Name Shape Purpose
-
Voltmeter
Use a voltmeter
designed to
withstand high
voltage rather
than a normal
voltmeter.
Voltage
shutoff
work/
restart
work
-
Insulation
resistance
tester
Use an equipment
able to measure
the resistance
value of a load to
which a voltage of
500 V is applied.
-
High
voltage
protectors
Use gloves that
withstand up to
600V and are long
enough to cover
the arms
-
Wear goggles if
necessary.
㻢㻜㻝㻥㻣㻣
㻢㻜㻝㻥㻣㻤
High voltage insulation gloves
㻢㻜㻝㻥㻣㻥
Protective goggles
㻢㻜㻝㻥㻤㻜
511793
Blind plug