Fail-Safe position setting
While holding the wheel or trig-
ger, tap the Fail-Safe position
button.
Battery fail-safe function
OFF, ON
Initial value: OFF
Fail-safe mode
Off, Hold, Fail-safe
1
(Battery fail-safe function ON/OFF)
Tap B-F/S (ON) or (OFF) of each channel to select ON/OFF.
2
(Battery fail-safe voltage setting)
Tap the voltage display of battery fail-safe
voltage. Value input buttons appear on the
Fail-Safe menu screen.
Use the [+] or [-] button to select the voltage.
*
The voltage setting is not possible with the S - FHSS system fixed at 3.8 V.
3
When finished, return to the Linkage menu screen by pressing
the HOME button.
B-F/S function ON/OFF & Battery Fail-safe voltage setting
Battery Fail-safe Voltage
F-4G
3.5 V-8.6 V
T-FHSS/T-FHSS SR
3.8,4.0,4.2,4.4,4.6,4.8,5.0,
5.3,5.6,5.9,6.2,6.5,6.8,7.1,7.4V
S-FHSS
Only 3.8V
Example:
Ni-MH/Ni-Cd: 4cell---3.8V
Ni-MH/Ni-Cd: 6cell---4.4V
LiFe: 2cell---4.75/4.8V
Li-Po: 2cell---5.5/5.6V
When the receiver power supply of an electric car uses a common power supply from an
ESC, we recommend that this function be set to OFF because the voltage supplied to the
receiver may drop momentarily and the battery fail-safe function may be activated.
(Preparation)
- Tap the fail-safe part of the channel you want to
set.
The mode list appears on the Fail-safe menu
screen.
1
(Mode selection)
Tap from the list and select the mode. To cancel,
tap [Cancel].
(Each channel can be individually set.)
Fail-safe mode selection
1
(Servo position setup)
Tap the [Mode] button of the channel you want to set, and set
that channel to the Fail-safe mode.
Hold the corresponding steering wheel, throttle trigger, or oth-
er control in the position you want the servo to move to when
the fail-safe function is activated, and tap the [Position] button.
The position is displayed as a value.
2
When finished, return to the Linkage menu screen by pressing
the HOME button.
Fail-safe function setup
2
When finished with Hold mode or Off mode setting, return to the Linkage menu screen by press-
ing the HOME button. When setting fail-safe, set the servo position by the following method.