EasyManua.ls Logo

GE Baker Hughes PanaFlow LC XMT1000 - H.3 Specifications; H.3.1 General; H.3.2 Physical; H.3.3 Communication

GE Baker Hughes PanaFlow LC XMT1000
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PanaFlow™ LC User’s Manual 143
Appendix H. Foundation Fieldbus Communication
H.3 Specifications
H.3.1 General
H.3.2 Physical
H.3.3 Communication
Manufacturer Name: BHGE
Manufacturer ID (Hex): 004745
Model: XMT1000
Device Type: 0010
FF Device Revision: For latest, see Fieldbus Foundation website
FISCO Compliant: Yes
Hazardous Location Certs: See drawing 752-584
ITK Revision: 6.2
Protocol: H1
Protocol Baud (bps): 31.25k
DD and CFF Files: For latest, see Fieldbus Foundation website
Meter Programmable through FF: Yes
Polarity Sensitive (Yes/No): No
Quiescent Current Draw (mA): 26
Working Voltage: 9-32 VDC
Stack Manufacturer: Softing AG
Backup LAS Capable: Yes*
Total Number of VCRs: 24
Fixed VCRs for Configuration: 1
*LAS means Link Active Scheduler. It can schedule a network if the main LAS fails.

Table of Contents

Related product manuals