PanaFlow™ LC User’s Manual 137
Appendix G. Wireless HART Communication
a. Select HART application
b. Press 2, Online
c. Press 2, Configure
d. Press 2, Manual Setup
e. Press 2, Wireless
f. Press 2, Join Device to Network
g. Enter the Network ID and Join Key for your network
G.2.4 Emerson Wireless Gateway Setup configuration
The following information will show how to configure the Wireless Gateway with a STATIC IP to a dedicated
PC, this can be useful as a diagnostic tool.
Note: This is not a typical end user application but can be used as a diagnostic tool at the customer site, the
gateway may already be setup at the customer site per their procedures.
1. Connect +24VDC power to the wireless Gateway. Refer to the label on the inside cover of the Gateway.
2. Connect a CROSSOVER cable from the Ethernet 1 port of the gateway and the Ethernet port on the PC.
3. Configure the PC TCP/IP Settings (Note this information can be found in the Gateway manual).
a. Open: A network settings in the PC control panel.
b. Select TCP/IP and Properties.
c. Record any current static IP settings, before making changes so that the PC can be returned to its
original state.
d. Select “Use the following IP Address” box.
e. Input 192.168.1.12 in the IP Address block.
f. Input 255.255.255.0 in the Subnet Mask.
g. Select OK for both TCP/IP and LAN properties Windows.
4. Disable Proxies.
a. Open the standard Web browser on the PC.
b. Navigate to
Tool->Internet Options->Connections->LAN Settings.
c. Uncheck the Proxy Server Box.
5. Configure the Wireless Gateway.
a. Under web server, type address https://192.168.1.10.
Log in as User: admin and Password: default.
b. Navigate to Setup->Internet Protocol Screen.
Verify the Specify an IP Address box is checked.