Chapter 2. Installation
32 PanaFlow™ LC User’s Manual
3. Thread CH1 UP transducer cable into upstream junction box of the transducer set you will use for
channel one. Repeat for CH1 DN and remaining channels.
4. Remove cover on transducer junction box and terminate BNC end of transducer cable to the BNC on
the transducer for each channel. Replace junction box covers.
5. Open cover to 6 channel junction box and make connections between transducer cable BNCs and
trunk cable BNCs. Verifying transducer cables have the same channel labels as the trunk cable wires.
Replace junction box cover.
6. Open the back lid of the XMT1000 meter to access the wiring connections of the meter.
7. Connect the MCX ends of the 6-connector cable to the corresponding labeled MCX connector in the
back
of the XMT1000 meter. UP1 must connect to UP1 and so on.
Figure 46: XMT1000 Channel Backplane