2-8 C70 CAPACITOR BANK PROTECTION AND CONTROL SYSTEM – INSTRUCTION MANUAL
ORDER CODES CHAPTER 2: PRODUCT DESCRIPTION
2
2.3 Order codes
The order code is on the product label and indicates the product options applicable.
The C70 is available as a 19-inch rack horizontal mount or reduced-size (¾) vertical unit and consists of the following
modules: power supply, CPU, CT/VT, contact input and output, transducer input and output, and inter-relay
communications. Module options are specified at the time of ordering.
Order codes are subject to change without notice. See the web page for the product for the latest options.
The order code depends on the mounting option (horizontal or vertical) and the type of CT/VT modules (enhanced
diagnostic CT/VT modules or HardFiber
TM
process bus modules). The HardFiber process bus module provides an interface
to HardFiber Bricks.
2.3.1 Order codes with enhanced CT/VT modules
Table 2-4: C70 order codes for horizontal units
The R-GOOSE protocol described in IEC 61850-8-1 is available through the IEC 61850 software option. R-GOOSE
security requires the CyberSentry software option.
For Japanese, the settings display in Japanese on the graphical front panel, while the keys printed on the panel are
in English.
High density input/output modules 6W and 6X are not for use with the SL low voltage power supply.
C70 - * ** - * * * - F ** - H ** - M ** - P ** - U ** - W/X ** Full Size Horizontal Mount
BASE UNIT C70 | | | | | | | | | | | Base Unit
CPU T | | | | | | | | | | RS485 with 3 100Base-FX Ethernet, multimode, SFP with LC
U | | | | | | | | | | RS485 with 1 100Base-TX Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode,
SFP with LC
V | | | | | | | | | | RS485 with 3 100Base-TX Ethernet, SFP with RJ-45
W | | | | | | | | | | RS485 with 2 100Base-FX Ethernet, multimode ST + 10/100Base-TX Ethernet, RJ-45
SOFTWARE OPTIONS 00 | | | | | | | | | No software options
03 | | | | | | | | | IEC 61850
12 | | | | | | | | | Enhanced capacitor bank control (time and date, capacitor control supervision,
automatic voltage regulator)
13 | | | | | | | | | Enhanced capacitor bank control and IEC 61850
A0 | | | | | | | | | CyberSentry Lvl 1
A3 | | | | | | | | | CyberSentry Lvl 1 and IEC 61850
AC | | | | | | | | | CyberSentry Lvl 1 and enhanced capacitor bank control
AD | | | | | | | | | CyberSentry Lvl 1, IEC 61850, and enhanced capacitor bank control
B0 | | | | | | | | | IEEE 1588
B3 | | | | | | | | | IEEE 1588 and IEC 61850
BC | | | | | | | | | IEEE 1588 and enhanced capacitor bank control
BD | | | | | | | | | IEEE 1588, IEC 61850, and enhanced capacitor bank control
C0 | | | | | | | | | Parallel Redundancy Protocol (PRP)
C3 | | | | | | | | | PRP and IEC 61850
CC | | | | | | | | | PRP and Enhanced Capacitor Bank Control
CD | | | | | | | | | PRP, IEC 61850, and Enhanced Capacitor Bank Control
D0 | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1
D3 | | | | | | | | | IEEE 1588, CyberSentry Lvl 1, and IEC 61850
DC | | | | | | | | | IEEE 1588, CyberSentry Lvl 1, and enhanced capacitor bank control
DD | | | | | | | | | IEEE 1588, CyberSentry Lvl 1, IEC 61850, and enhanced capacitor bank control
E0 | | | | | | | | | IEEE 1588 and PRP
E3 | | | | | | | | | IEEE 1588, PRP, and IEC 61850
EC | | | | | | | | | IEEE 1588, PRP, enhanced capacitor bank control
ED | | | | | | | | | IEEE 1588, PRP, IEC 61850, and enhanced capacitor bank control
F0 | | | | | | | | | PRP and CyberSentry Lvl 1
F3 | | | | | | | | | PRP, CyberSentry Lvl 1, and IEC 61850
FC | | | | | | | | | PRP, CyberSentry Lvl 1, and enhanced capacitor bank control
FD | | | | | | | | | PRP, CyberSentry Lvl 1, IEC 61850, and enhanced capacitor bank control
G0 | | | | | | | | | IEEE 1588, PRP, and CyberSentry Lvl 1
G3 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
GC | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and enhanced capacitor bank control
GD | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and enhanced capacitor bank control
J0 | | | | | | | | | IEC 60870-5-103
J3 | | | | | | | | | IEC 60870-5-103 and IEC 61850
JC | | | | | | | | | IEC 60870-5-103 and enhanced capacitor bank control
JD | | | | | | | | | IEC 60870-5-103, IEC 61850, and enhanced capacitor bank control
K0 | | | | | | | | | IEEE 1588, PRP, and IEC 60870-5-103
K3 | | | | | | | | | IEEE 1588, PRP, IEC 60870-5-103, and IEC 61850
KC | | | | | | | | | IEEE 1588, PRP, IEC 60870-5-103, and enhanced capacitor bank control
KD | | | | | | | | | IEEE 1588, PRP, IEC 60870-5-103, IEC 61850, and enhanced capacitor bank control
L0 | | | | | | | | | IEC 60870-5-103, IEEE 1588, PRP, and CyberSentry Lvl 1
L3 | | | | | | | | | IEC 60870-5-103, IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850
LC | | | | | | | | | IEC 60870-5-103, IEEE 1588, PRP, CyberSentry Lvl 1, and enhanced capacitor bank
control
LD | | | | | | | | | IEC 60870-5-103, IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and enhanced
capacitor bank control
MOUNT/COATING H | | | | | | | | Horizontal (19” rack)
A | | | | | | | | Horizontal (19” rack) with harsh-environment coating
FRONT PANEL + INTERFACE C | | | | | | | English display
P | | | | | | | English display with 4 small and 12 large programmable pushbuttons
D|||||| |French display

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE C70 and is the answer not in the manual?

GE C70 Specifications

General IconGeneral
BrandGE
ModelC70
CategoryProtection Device
LanguageEnglish

Related product manuals