A-28 C70 CAPACITOR BANK PROTECTION AND CONTROL SYSTEM – INSTRUCTION MANUAL
FLEXANALOG ITEMS APPENDIX A: FLEXANALOG OPERANDS
A
10720 SRC 5 Ic Harm[19] % Source 5 phase C current nineteenth harmonic
10721 SRC 5 Ic Harm[20] % Source 5 phase C current twentieth harmonic
10722 SRC 5 Ic Harm[21] % Source 5 phase C current twenty-first harmonic
10723 SRC 5 Ic Harm[22] % Source 5 phase C current twenty-second harmonic
10724 SRC 5 Ic Harm[23] % Source 5 phase C current twenty-third harmonic
10725 SRC 5 Ic Harm[24] % Source 5 phase C current twenty-fourth harmonic
10726 SRC 5 Ic Harm[25] % Source 5 phase C current twenty-fifth harmonic
10735 SRC 6 Ia THD % Source 6 phase A current total harmonic distortion
10736 SRC 6 Ia Harm[2] % Source 6 phase A current second harmonic
10737 SRC 6 Ia Harm[3] % Source 6 phase A current third harmonic
10738 SRC 6 Ia Harm[4] % Source 6 phase A current fourth harmonic
10739 SRC 6 Ia Harm[5] % Source 6 phase A current fifth harmonic
10740 SRC 6 Ia Harm[6] % Source 6 phase A current sixth harmonic
10741 SRC 6 Ia Harm[7] % Source 6 phase A current seventh harmonic
10742 SRC 6 Ia Harm[8] % Source 6 phase A current eighth harmonic
10743 SRC 6 Ia Harm[9] % Source 6 phase A current ninth harmonic
10744 SRC 6 Ia Harm[10] % Source 6 phase A current tenth harmonic
10745 SRC 6 Ia Harm[11] % Source 6 phase A current eleventh harmonic
10746 SRC 6 Ia Harm[12] % Source 6 phase A current twelfth harmonic
10747 SRC 6 Ia Harm[13] % Source 6 phase A current thirteenth harmonic
10748 SRC 6 Ia Harm[14] % Source 6 phase A current fourteenth harmonic
10749 SRC 6 Ia Harm[15] % Source 6 phase A current fifteenth harmonic
10750 SRC 6 Ia Harm[16] % Source 6 phase A current sixteenth harmonic
10751 SRC 6 Ia Harm[17] % Source 6 phase A current seventeenth harmonic
10752 SRC 6 Ia Harm[18] % Source 6 phase A current eighteenth harmonic
10753 SRC 6 Ia Harm[19] % Source 6 phase A current nineteenth harmonic
10754 SRC 6 Ia Harm[20] % Source 6 phase A current twentieth harmonic
10755 SRC 6 Ia Harm[21] % Source 6 phase A current twenty-first harmonic
10756 SRC 6 Ia Harm[22] % Source 6 phase A current twenty-second harmonic
10757 SRC 6 Ia Harm[23] % Source 6 phase A current twenty-third harmonic
10758 SRC 6 Ia Harm[24] % Source 6 phase A current twenty-fourth harmonic
10759 SRC 6 Ia Harm[25] % Source 6 phase A current twenty-fifth harmonic
10768 SRC 6 Ib THD % Source 6 phase B current total harmonic distortion
10769 SRC 6 Ib Harm[2] % Source 6 phase B current second harmonic
10770 SRC 6 Ib Harm[3] % Source 6 phase B current third harmonic
10771 SRC 6 Ib Harm[4] % Source 6 phase B current fourth harmonic
10772 SRC 6 Ib Harm[5] % Source 6 phase B current fifth harmonic
10773 SRC 6 Ib Harm[6] % Source 6 phase B current sixth harmonic
10774 SRC 6 Ib Harm[7] % Source 6 phase B current seventh harmonic
10775 SRC 6 Ib Harm[8] % Source 6 phase B current eighth harmonic
10776 SRC 6 Ib Harm[9] % Source 6 phase B current ninth harmonic
10777 SRC 6 Ib Harm[10] % Source 6 phase B current tenth harmonic
10778 SRC 6 Ib Harm[11] % Source 6 phase B current eleventh harmonic
10779 SRC 6 Ib Harm[12] % Source 6 phase B current twelfth harmonic
10780 SRC 6 Ib Harm[13] % Source 6 phase B current thirteenth harmonic
10781 SRC 6 Ib Harm[14] % Source 6 phase B current fourteenth harmonic
10782 SRC 6 Ib Harm[15] % Source 6 phase B current fifteenth harmonic
Address FlexAnalog name Units Description