GEDA
®
Temporary Construction Hoist PH 650
Operating Manual Page 46 of 64 BL148GB2017 / 11
11 Safety and emergency equipment
Extensive safety and emergency equipment guarantee that people are
efficiently separated from any hazards.
The hoist has the following safety and emergency equipment:
• Base enclosure
• Safety gear
• Car door lock
• Intercom system
• Locks to prevent unauthorised use
• EMERGENCY STOP
• EMERGENCY limit switches
• EMERGENCY lighting
• EMERGENCY lowering device
11.1 EMERGENCY STOP
Press EMERGENCY STOP only in an emergency.
The hoist has 5 EMERGENCY STOP buttons:
• Car control unit
• Car roof (maintenance control)
• Ground-station switch box
• Drop-test control
• Assembly control
Triggering an EMERGENCY STOP/hoist shut-down in events of
emergency
Manually press the EMERGENCY STOP.
End the EMERGENCY STOP situation
Manually pull out the EMERGENCY STOP.
11.1.1 Defect after an EMERGENCY STOP situation
If an EMERGENCY STOP situation cannot be rectified, the hoist must be
turned off at the mains switch and secured against unauthorised switch-on.
Inform the supervisor.
Danger to life
Due to the hoist being switched on during
maintenance/servicing tasks or if there is a defect.
Secure the main switch with a padlock against