GEDA
®
Temporary Construction Hoist PH 650
Operating Manual Page 54 of 64 BL148GB2017 / 11
12 Rescuing persons trapped inside
Rescue may become necessary if, e.g.
• there is no mains voltage.
• malfunctions in the electrical system.
• the drive has failed.
• the safety gear has triggered.
If the hoist supervisor does not feel sufficiently qualified to organise and
carry out the rescue, the relevant authorities must also be notified
(fire brigade, technical support, factory security office).
12.1 Basic conduct in the event of a rescue/malfunction
• Remain calm and do not act hastily.
• Get an overview of the situation.
• Keep unauthorised persons away.
• Contact any persons trapped in the car.
• Try to find out what has caused the malfunction/defect in the
system.
− Power supply failure (emergency lighting on).
− Safety gear triggered.
− If appropriate, error code on the landing display
• Inform any people trapped in the car about the further procedure.
• Inform your supervisor about the malfunction.
• Inform any rescue services.