enclosure / car
does not open
Car is not exactly at the ground
station
Switch / door lock defective
Move car until it is in front of
the landing door
Door EMERGENCY unlock.
Replace defective lock / switch
at the landing.
(Stop Next Landing)
Error detecting the landing
approach bar
Faulty sensor or distance to
the approach bar too large
Use the button (3) carry out a
reference run to the ground
station (refer to Chapter
12.3)
Check/adjust sensor and
reduced speed
Deficiency of grease in the
lubrication device (more than 4
cartridge
13.2.1 Motor is not producing full output
Voltage drop of more than 10 % of the rated voltage.
Select a supply cable with a greater cross-section.
The integrated thermoswitch switches off the frequency converter when
overloaded. Work can continue after a certain cool-down period (possibly
reduce load).
Refrain from repeated overheating/overloading. - Otherwise the
service life of the motor/brakes will be shortened.
13.2.2 Lifting platform moved too high
The car emergency limit switch can reach the upper EMERGENCY limit
switch bar if
o the sensing device is defective;
o there is a fault in the electrical system.
Action:
• Operate motor brake using the release lever (refer to Chapter 11.11)