Rev. 00 04/19
86
Maintenance / Repairs OptiCenter OC06
– The key can be pressed once again if necessary. Otherwise the
next cleaning step is activated.
27. The following screen is displayed:
– The fresh powder pump is cleaned
28. The booth can now be cleaned: Activate the corresponding
command on the MagicControl control unit
– The powder is fed into the powder bag
29. Once the booth has been cleaned, reposition the GK coupling in the
cleaning position
30. The cleaning of the recovery hoses starts automatically (sensor
monitored)
31. The process is complete when this screen is displayed:
Any individual step can be repeated as needed by pressing the
corresponding key again.
– Only the selected cleaning step is carried out.