AutoVu SharpX mobile installation
tip.genetec.com | AutoVu Hardware Guide for SharpX Mobile Installation
EN.410.018-XS(6) | Last updated: October 6, 2016 17
2 Power up the LPR Processing Unit and wait 1 minute to ensure that the LPR camera ports are
powered-up.
3 Connect the SharpX camera and CAT5e cables to the LPR Processing Unit.
The status lights on the DATA LINK port do not light up during cable testing.
4 Set the Cable Tester to Active mode.
5 Set the Cable Tester to SharpXmode.
NOTE: Using the wrong Mode will result in incorrect test results.
6 Press and release the Push To Test button.
7 Verify that all wire indicator LEDs are solid green. If they are not solid green, redo both the Passive
test and the Active test to confirm that the source of the error is the LPR Processing Unit.
If all wire LEDs are solid green, the cable and LPR Processing Unit ports have passed the active test.