AutoVu SharpX mobile installation
tip.genetec.com | AutoVu Hardware Guide for SharpX Mobile Installation
EN.410.018-XS(6) | Last updated: October 6, 2016 70
Aligning the SharpX with the target
After you set up and properly position the tripod, use the live feed in the Sharp Portal (advanced
mode) to align the camera with the target.
What you should know
If the system includes an X2S LPR Processing Unit, you will need to open a separate Sharp Portal for
each of the SBCs. For more information, see Sharp Portal instructions.
To align the camera with the target:
1 Log on to the Sharp Portal.
After entering the password and selecting your language, press Ctrl + Enter to log on in Advanced
mode, which gives you access to additional settings not found in regular mode.
2 In the Live Feed tab, select the LPR Camera feed in the Camera selection drop-down list.
Because you logged on in Advanced mode, crosshairs are displayed on the LPR camera feed.
3 Adjust the pan/tilt angles of the camera as needed to align the crosshairs with the target.
The camera is aligned.
After you finish
Repeat the procedure for your other cameras, as needed.