AutoVu SharpX mobile installation
tip.genetec.com | AutoVu Hardware Guide for SharpX Mobile Installation
EN.410.018-XS(6) | Last updated: October 6, 2016 36
E: Securing screws
Example
Watch this video to learn more. Click the Captions icon (CC) to turn on video captions in one of the
available languages.
Related Topics
System status LEDs on the LPR Processing Unit on page 74
Securing wires using tension clamp connectors on page 31
Wire ferrules for a SharpX installation
When connecting the power port to the LPR Processing Unit in a SharpX installation, you can use the
ferrule crimping tool that is included with the AutoVu Alignment Kit to crimp a ferrule to the end of
each stripped wire for a more secure connection.
The following table shows the appropriate ferrules for each wire gauge:
Wire AWG Ferrule color
14 Blue
16 Black
18 Red
20 Grey
24 Violet