G-858BP Backpack Mag Operators Manual
Adjusts the amount the pitch of the woowee changes with varying field readings.
QC warning volume
1 is softest, 9 loudest
QC warning level
Sets the threshold for the QC warning to be emitted. If the QC exceeds this threshold, the warning is
sounded.
Full Scale
Sets the trace width full-scale of the display.
Readings per screen
Sets the vertical scale of the trace display. Higher values means the trace moves more slowly down the
screen.
EDIT LINE AND MARK
Opens the data editing menu. See detail below.
CENTER TRACE
Centers the trace in the sweep display.
Pop up Menus
From the acquisition display, there are two quick pop up menus that are accessible:
Audio Key
Pressing the audio key will bring up an audio adjust indicator. Then the up and down keys will adjust
the volume, while the right and left arrows will adjust the pitch of the woowee. The audio adjust indicator
will disappear after a few seconds.
Scale Key
Pressing the scale key will bring up an scale adjust indicator. Then the up and down keys will adjust
the speed of the sweep (readings shown per page), while the right and left arrows will adjust the full scale
(in nT). The scale adjust indicator will disappear after a few seconds.
Pausing
Pressing the PAUSE key while acquiring data will temporarily stop data acquisition. At this point,
you may do any of the following:
Press PAUSE. This will re-start the acquisition process.
Press MARK. This will enter the current position. Do this only if you are currently at one of your
way points. Only one MARK key press is allowed. The instrument will stay in pause mode.
Press END LINE. This will enter the END LINE position. Do this only if you are at the end of
the line. The instrument will switch out of pause mode, and into the normal between-line state. Next, press
the MARK key to start taking data.
41

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Geometrics G-858BP and is the answer not in the manual?

Geometrics G-858BP Specifications

General IconGeneral
BrandGeometrics
ModelG-858BP
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals