Pre-requisites for Installing Omnia in FlexPay IV Configuring FlexPay IV
MDE-5369E FlexPay™ IV (with Omnia) Programming and Service Manual · April 2020 Page 4-3
The internal scheme becomes 172.20.100.1/3 (A/B). The jumper on the Peripheral Interface
PCB (PIP) board determines A or B side.
Notes: 1) When running Omnia with a Commander POS, the CRIND Baud Rate must be set to
9600 Baud in the CRIND settings in the UPM, and at the Commander POS.
2) All other POS types can remain default 4800 Baud.
Install hardware. For more information, refer to MDE-5402 FlexPay IV Applause Media Kit
with Omnia (M16183K001) Installation Instructions.
Note: If a FlexPay IV CRIND is already installed in the dispenser, restore the default IP
address of the card reader after Omnia is installed.
To configure final UPM settings in the Maintenance Menu, proceed as follows:
5 In the Device Config menu, press <1> for Device
Selection.
6 In the Device Selection, press <2> to set the
Communication Module to be OMNIA and press the
following:
•Press OK to Save Changes and Exit.
•Press CANCEL.
•Press CANCEL to restart the system.
Description Screen
1Press <8> to open the Secure Menu.
Description Screen