EasyManua.ls Logo

GKB 4CH - Page 47

Default Icon
129 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GKB 4CH/8CH VFire Server
47
Open(Level). Please check the signal type, normally close or normally open,
connected to the alarm input terminal on the rear panel of the system. If
there’s no signal connected, please select N/A Not Available, and the
following items will not be settable. The default setting is Open. Please note
that for Close(Level) and Open(Level), the Duration and Post-record mentioned
below will keep being activated when the alarm input is at alarm state.
n Title The title (Max. 8 characters) of this alarm input. Please follow the Text
Input method described in Section 4.1 to modify this item.
n Delay the alarm input will be treated as if it’s triggered Delay time (0-15
seconds) later after being really triggered, 0 sec. for no delay.
n Focus Camera – the camera corresponding to this alarm input.
n Duration response duration to define at most how long (in seconds) the
Alarm Out relay and the Buzzer will keep being triggered after this alarm input
is triggered or returns to normal. Press +/- buttons to adjust the value (3
seconds - 60 minutes, discrete, ‘-‘ for ‘Forever’).
n Goto Preset to define the preset position to go to for the Focus Camera if this
alarm input is triggered and the Focus Camera is a PTZ camera. For more
details about preset locations, please refer to Chapter 7 PTZ Control.
n Pre-record to define how long before this alarm input is triggered the Focus
Camera shall be intensively recorded at Pre-record IPS. Press +/- buttons to
adjust the value (0-10 seconds, discrete). Please note that the actual
pre-record time may be shorter than the value set if the total size of the
pre-record pictures exceeds the pre-record buffer size of the system.
n Post-record to define how long after this alarm input is triggered or returns to
normal the Focus Camera shall be intensively recorded at Event Record IPS.
Press +/- buttons to adjust the value (0 second - 60 minutes, discrete).
n Alarm Out to define which Alarm Output will be triggered when this alarm
input is triggered. Press +/- buttons to select none (N/A) or one of the Alarm
Outputs (NC (1), NO (2)).
n Buzzer to activate the internal Buzzer or not when this alarm input is
triggered. Press ENTER or +/- to check/uncheck this item. The default
setting is “ˇ” - checked.
n Log to log to event logs or not. Press ENTER or +/- to check/uncheck this
item. The default setting is “ˇ” - checked.