Configure the maximum digits allowed to dial in the keypad. Once the
configured condition satisfied, the device will send out the digit to call
automatically without pressing #. Disabled if set to 0.
Defines the timeout (in seconds) for no key entry. If no key is pressed after
the timeout, the digits will be sent out without pressing #. The default value
is 4 seconds. The valid range is from 1 to 15.
Configure a schedule for the Doorbell button, once configured, the
doorbell with turn ON/OFF based on configured schedule. Default setting
is “All Day”.
Three options are available: Private Card PIN, Unified PIN or Card and
Private PIN.
Private PIN: Means every member has a private PIN, the GDS will
record who unlocked the door every time. Users need to enter the
following sequence from the GDS3705 to open the door [*Virtual
Number*Private PIN#].
Notes:
1. When Local PIN type is set to private PIN, users can also open
the door by swiping their cards.
2. If “Disable Keypad SIP Number Dialing” is checked, users will be
able to open door using private PIN with following sequence
[Private PIN#].
Note: Door can still be opened by Card and with the sequence
[*Virtual Number*Private PIN#].
For more details and conditions, refer to [Disable Keypad SIP
Number Dialing].
Unified PIN: Means all members share a same PIN to unlock the
door. Users need to enter the following sequence from the GDS3705
keypad to open the door [*Local PIN to Open Door#].
Card & Private PIN: Means every member needs to swipe his card
and enter his private PIN to open the door using the following
sequence [Swipe the card + * Private PIN#]