8 Electrical Adjustment
(12) Press the ENTER key when the gap became to 1.1 mm.
(13) When the height is not same height, press the F4 key to adjust the height.
Adjust height using the up or the down position key.
(14) Mountabertippeninthe2ndpenstation.
(15) Press the F2 key, and the pen holder moves to the exchange position.
(16) Turnthepenbyhandmanually,andthenconrmthepenturnssmoothlywithoutplay.
(17) Presstherightkeytoconrmthatthepenexchangingisperformedcorrectly.
This test performs by the -0.3 mm, the 0 mm, the +0.3 mm from the setting value.
When the -0.3 from the setting value, it will push a pen a little.
(18) If the pen exchanging is performed correctly, press the ENTER key, the following menu is displayed.
(19) Turn off the power for the plotter. (When other adjustment is going to perform continuously it does not
need to turn off the power.)